Air Permeability Tester Main Page
MS Excel Version of Chart - original
| Frazier Differential Pressure Air Permeability Specifications and Comparison Chart - 2005 Models | |||||
| Frazier Precision Instrument Company, Inc. - 925 Sweeney Drive, Hagerstown, MD 21740 USA | |||||
| Phone (301) 790-2585 Fax (301) 790-2589 | |||||
| http://www.frazierinstrument.com | Low Pressure | High Pressure | Frazier 2000 (1) | Frazier 2000 (2) | Low Pressure with |
| email: sales@frazierinstrument.com | Air Permeability | Air Permeability | Air Permeability | Air Permeability Retrofit | Frazier 2000 Retrofit (1) |
| Model LP | Model HP | Model A | Model AR | Model LPAR | |
| Manual Operation | Manual Operation | Computer Operation | Computer Operation | Computer Operation | |
| Part Number | FAP0000LP | FAP0000HP | FAP0000F2A | FAP0000F2AR | FAP0000LPAR |
| Pressure Drop or | |||||
| Differential Pressure Range (delta P) (8)(9) | (8) | (8) | (8)(9) | (9) | (8)(9) |
| Differential Pressure Range - inches of H2O | 0.00 to 1.00 | 0.00 to 0.55; 1.0 to 21.0 | 0.00 to 21.0 (3) | 0.00 to 21.0 (3) | 0.00 to 1.00 (3) |
| Differential Pressure Range - millimeters of H2O | 0.0 to 25.4 | 0.0 to 14.0; 25.4 to 533.4 | 0.0 to 533.4 (3) | 0.0 to 533.4 (3) | 0.0 to 25.4 (3) |
| Differential Pressure Range - pascals | 0.0 to 249 | 0.0 to 137; 249 to 5231 | 0.0 to 5231 (3) | 0.0 to 5231 (3) | 0.0 to 249 (3) |
| Permeability Range (Air Flow) (8)(9) | (8) | (8) | (8)(9) | (9) | (8)(9) |
| Permeability Range - Cu. Ft./Sq. Ft. of Sample/Minute (5) | 0.5 to 700 (4) | 0.5 to 5400 (4) | 0.5 to 5400 (4) | 0.5 to 5400 (4) | 0.5 to 700 (4) |
| Permeability Range - Cu. cm/Sq. cm of Sample/Second | 0.5 to 356 | 0.5 to 2743 | 0.5 to 2743 | 0.5 to 2743 | 0.5 to 356 |
| Measuring Accuracy - 'bias' | |||||
| Repeatablitiy of Instrument - error % of Reading | +/-0.5% | +/-0.5% | +/-0.5% | +/-0.5% | +/-0.5% |
| Repeatablitiy among "Frazier" brand Instruments - | +/-2% (6) | +/-2% (6) | +/-2% (6) | +/-2% (6) | +/-2% (6) |
| error % of Reading (6) | |||||
| Test Methods and Standards | (T1)(T2)(T3)(T4)(T5)(T6) | (T1)(T2)(T3)(T4)(T5)(T6) | (T1)(T2)(T3)(T4)(T5)(T6) | (11) | (T1)(T2)(T3)(T4)(T5)(T6) |
| (T7)(T8)(T9)(T10)(T11) | (T7)(T8)(T9)(T10)(T11) | (T7)(T8)(T9)(T10)(T11) | (T7)(T8)(T9)(T10)(T11) | ||
| (T12)(T13)(T14)(T15)(T16) (T17) (T18) | (T12)(T13)(T15)(T16)(T17)(T18) | (T12)(T13)(T14)(T15)(T16)(T17)(T18) | (T12)(T13)(T14)(T15)(T16)(T17)(T18) | ||
| Dimensions of Unit - Installed in table (12) | 48"Wx24"Dx50"H (12) | 48"Wx24"Dx61.5"H (12) | 48"Wx24"Dx61.5"H (12) | 11.5"Wx11.5"Dx7"H (7) | 48"Wx24"Dx50"H (12) |
| Prices FOB or CIF Hagerstown, MD USA | call or email | call or email | call or email | call or email | call or email |
| Notes (#): | |||||
| (1) Air Permeability Tester w/ Computerized Data Collection | |||||
| (2) Used to Computerize Data Collection when added to any Model of Frazier Differential Pressure Air Permeability Tester | |||||
| (3) Special Order Frazier 2000 Sensors can extend range up to 200 inches; 5080 mm; 49816 pascals | |||||
| (4) Air Flow Range can be extended above and below specified ranges w/ special nozzles (9 standard nozzles included) - call for additional details | |||||
| (5) Often referred to as the "Frazier Number" or CFM | |||||
| (6) Proprietary Frazier calibration procedures give increased repeatability not available among non-Frazier testers | |||||
| (7) Dimensions of Electronic Unit | |||||
| (8) Standard units for instrument are inches of H2O and Cu. Ft./Sq. Ft./Minute (specify types of optional units needed for manually operated instruments) | |||||
| (9) Additional standard and user units can be easily set on computer operated units | |||||
| (10) Specs of Model HP with the addition of Model AR would be the same as Model A | |||||
| (11) When Model AR is added to Model LP, see Model LPAR Test Methods; When Model AR is added to Model HP, see Model A Test Methods | |||||
| (12) All models can be removed from table for portability or installed in laboratory casework or production lines | |||||
| Test Methods (T#): | |||||
| (T1) ASTM D737; (T2) ASTM F778; (T3) ASTM D1117; (T4) ASTM D461; (T5) ASTM C522; (T6) DART 70.0; (T7) Federal Test Method #191; (T8) Federal Test Method #5450 | |||||
| (T9) ASA No. L154.51; (T10) Tappi T251; (T11) IST 70.1-92; (T12) ISO 9237; (T13) DIN 53887; (T14) Edana 140.1-81; (T15) JIS L1096; (T16) ASTM D3574; (T17) ASTM D6539 (T18) ISO 7231 | |||||
| There are many U.S. and worldwide standards that are based on the standards above - please call or email us if you have an air permeability standard that you need to use - we can let you know if our tester will perform the test. | |||||
| Product prices, appearance, and specifications are subject to change at any time and do not include shipping, handling, or taxes. | |||||
| Additional Information can be found at: http://www.frazierinstrument.com | Frazier, The Frazier, Frazier Number, and Frazier 2000 are Trademarks of Frazier Precision Instrument Company, Inc. | ||||